EZZ0826I
PREFERRED AND BACKUP PARAMETERS ARE REQUIRED ON THE VIPADISTRIBUTE STATEMENT WHEN DISTMETHOD IS HOTSTANDBY

Explanation

Because the distribution method is HOTSTANDBY, there must be exactly one DESTIP address that is specified as PREFERRED and at least one DESTIP address that is specified as BACKUP.

System action

If processing an initial profile or a VARY TCPIP,,OBEYFILE command, TCP/IP continues, but the VIPADISTRIBUTE statement is ignored.

This message is also displayed as part of VARY TCPIP,,SYNTAXCHECK processing when the VARY TCPIP,,SYNTAXCHECK command detects this error in a profile data set. No changes are applied to the active configuration by VARY TCPIP,,SYNTAXCHECK processing.

Operator response

Contact the system programmer.

System programmer response

Do the following steps to correct the problem:

  1. Add the missing parameters on the configuration statement.
  2. If this message was displayed as a result of a VARY TCPIP,,SYNTAXCHECK command, issue the command again to verify that you have corrected all syntax errors in the profile. Otherwise, issue the VARY TCPIP,,OBEYFILE command with the changed configuration statement.

See the information about the VIPADYNAMIC statement in z/OS Communications Server: IP Configuration Reference.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Configuration & Initialization

Module

EZACFPVA

Routing code

10

Descriptor code

12

Automation

This message is directed to the console. You can use automation to detect and respond to TCP/IP profile errors reported during initial profile and VARY TCPIP,,OBEYFILE processing.

This message can also be displayed during VARY TCPIP,,SYNTAXCHECK processing. Because the VARY TCPIP,,SYNTAXCHECK command does not affect the active configuration, you might want to adjust your automation to ignore the configuration messages that are displayed after EZZ0061I and before EZZ0065I.

Example

EZZ0826I PREFERRED AND BACKUP PARAMETERS ARE REQUIRED ON THE VIPADISTRIBUTE STATEMENT WHEN DISTMETHOD 
         IS HOTSTANDBY                                                 