z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ0715I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ0715I
IPV6 ADDRESS ON LINE lineno IS NOT VALID

Explanation

An IPv6 address that was not valid was specified on the IP configuration statement at line lineno.

In the message text:
lineno
The line number in the profile where the error was found

See the z/OS Communications Server: IP Configuration Reference for more information about the IP configuration statement where the error was found.

System action

If processing an initial profile or a VARY TCPIP,,OBEYFILE command, TCP/IP ignores the statement.

This message is also displayed as part of VARY TCPIP,,SYNTAXCHECK processing when the VARY TCPIP,,SYNTAXCHECK command detects this error in a profile data set. No changes are applied to the active configuration by VARY TCPIP,,SYNTAXCHECK processing.

Operator response

Contact the system programmer.

System programmer response

  • Correct the statement.
  • If this message was displayed as a result of a VARY TCPIP,,SYNTAXCHECK command, issue the command again to verify that you have corrected all syntax errors from the profile. Otherwise, use the VARY TCPIP,,OBEYFILE command to rerun the configuration statement.

Module

EZACFV6

Automation

This message is directed to the console. You can use automation to detect and respond to TCP/IP profile errors reported during initial profile and VARY TCPIP,,OBEYFILE processing.

This message can also be displayed during VARY TCPIP,,SYNTAXCHECK processing. Because the VARY TCPIP,,SYNTAXCHECK command does not affect the active configuration, you might want to adjust your automation to ignore the configuration messages that are displayed after EZZ0061I and before EZZ0065I.

Procedure name

processInterface

Example

EZZ0715I IPV6 ADDRESS ON LINE 42 IS NOT VALID