To invoke CEEXOPT and create the CEEUOPT object module, follow
these steps:
- Copy member CEEUOPT from CEE.SCEESAMP into CEEWUOPT in place of
the comment lines following the SYSIN DD statement.
- Change the parameters on the CEEXOPT macro statement in CEEUOPT
to reflect the values you chose for this application-specific runtime
options module.
- Code just the options you want to change. Options omitted from
CEEUOPT remains the same as the defaults.
- Change DSNAME=YOURLIB in the SYSLMOD DD statement to
the name of the partitioned data set into which you want your CEEUOPT
module to be link-edited.
Note: If you have a CEEUOPT module
in your current data set, it is replaced by the new version.
- Check the SYSLIB DD statement to ensure that the data set names
are correct.
CEEWUOPT should run with a condition code of 0.