Register 15 contains a return code indicating if an environment
was successfully initialized. Possible return codes
(in
decimal) are:
- 0
- A new environment was successfully initialized.
- 4
- The function code is not valid.
- 8
- All addresses in the table were not resolved. This can occur if
a LOAD failure was encountered or a routine within the table was not
generated by a Language Environment-conforming
HLL.
- 12
- Storage for the preinitialization environment could not be obtained.
- 32
- An unhandled error condition was encountered. This error is a
result of a program interrupt or other abend that occurred that prevented
the preinitialization services from completing.
- 40
- An entry in the PreInit table is an XPLINK subroutine
and the environment is a non-XPLINK sub environment.
This entry is not valid.