Informational options created for all data set types

z/OS Infoprint Server Operation and Administration
SA38-0693-00

Informational options created for all data set types

-OJOBNAME (ojobn)
Set to the JES job name associated with the print data set.
-OUSERID (ous)
Set to the z/OS user id associated with the print data set.
-ONODEID (ono)
Set to the z/OS node id associated with the print data set.
-OPROGRAMMER (opr)
Set to the value of the programmer name from the JCL JOB statement. If not specified, this option is not created.
-OPASSTHRU (opa)
This option can consist of this sub-option:
-SEGMENTID
Set to the value of the segment id of the print data set, if one exists. If it does not exist, the SEGMENTID sub-option is not included the PASSTHRU option.
-OADDRESS1
Set to the value of the first address subparameter from the ADDRESS parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OADDRESS1 option is not created.
-OADDRESS2
Set to the value of the second address subparameter from the ADDRESS parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OADDRESS2 option is not created.
-OADDRESS3
Set to the value of the third address subparameter from the ADDRESS parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OADDRESS3 option is not created.
-OADDRESS4
Set to the value of the fourth address subparameter from the ADDRESS parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OADDRESS4 option is not created.
-OBUILDING (obu)
Set to the value of the BUILDING parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OBUILDING option is not created.
-ODEPARTMENT (ode)
Set to the value of the DEPT parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the ODEPARTMENT option is not created.
-ONAME (ona)
Set to the value of the NAME parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the ONAME option is not created.
-OROOM (oro)
Set to the value of the ROOM parameter on the OUTPUT JCL statement. If not specified, set to the ROOM parameter on the JOB JCL statement. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If no room value is specified, the OROOM option is not created.
-OTITLE (oti)
Set to the value of the TITLE parameter if specified on JCL. This value can also be specified in an Infoprint Server job attribute and in the printer definition. If not specified, the OTITLE parameter is not created.