Procedure for specifying attributes

z/OS Infoprint Server Operation and Administration
SA38-0693-00

Procedure for specifying attributes

To fill in ISPF panels to specify a fixed-pitch font:

  • If the printer is controlled by PSF, name the font in the Character sets field on the Allocation panel.
  • If the printer is controlled by IP PrintWay™, and IP PrintWay uses the AFP to PCL transform or the AFP to PostScript transform for line data, name the font in the Character sets field on the Allocation panel.
  • If the printer is controlled by IP PrintWay, and IP PrintWay does not use a transform for line data, specify PCL commands to select the font in the Document header field on the IP PrintWay Options panel. Also, be sure to reset the printer to its original state in the Document trailer field.
Tip:
If you need to specify the same fields in more than one printer definition, specify the fields in components. Then, include those components in each printer definition to which the components apply.

Examples

Example 1. Specifying a fixed-pitch font for a printer controlled by PSF

This example shows how to fill in the ISPF panels to specify a fixed-pitch font for a printer controlled by PSF. Also, use this example if the printer definition is controlled by IP PrintWay and IP PrintWay uses the AFP to PCL or the AFP to PostScript transform.

                                   Allocation

·
·
·
Resource Related Values:
·
·
·
Character sets . 60DB ____ ____ ____
·
·
·

In this example, PSF, the AFP to PCL transform, and the AFP to PostScript transform use the Gothic Text Latin1, fixed-pitch, font. The pitch is 10 characters per inch.

Example 2. Specifying a fixed-pitch font for a printer controlled by IP PrintWay

This example shows how to fill in the ISPF panels to specify PCL commands to select a fixed-pitch font to print the data and then reset the printer to its default settings.

                           IP PrintWay Options
 

·
·
·
Document header . . <ESC>%-12345X<ESC>E<ESC>(8U<esc>(s0p10h0s3b4102T(extend) / Translate document header Document trailer . . <ESC>E<ESC>%-12345X (extend) / Translate document trailer
·
·
·

The PCL commands in the Document header field reset the printer to its default settings and then select the fixed-pitch Letter Gothic font. The PCL commands shown mean:

Command
Meaning
<ESC>%-12345X
Reset the printer and enter PJL mode.
<ESC>E
Reset the printer.
<ESC>(8U
Select the Roman-8 symbol set.
<ESC>(s0p10h0s3b4102T
Set fixed spacing (0p), 10 characters per inch (10h), upright style (0s), bold weight (3b), and Letter Gothic typeface (4102T).
Notes:
  1. The last letter of each command is a capital letter to denote the end of the command.
  2. When you select the NetSpool Convert to PCL formatting option, the value in the Print density field overrides the number of characters per inch set in the Document header field.