z/OS Infoprint Server Operation and Administration
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF


Procedure for specifying attributes

z/OS Infoprint Server Operation and Administration
SA38-0693-00

Procedure for specifying attributes

To request that NetSpool not convert the input data stream:

  1. On the NetSpool Options panel, specify these fields:
    • Formatting field: Select the None option.
    • Maximum record size field: (Optional) Specify the maximum size of the variable-length records. Allowed values are 1- 32752. The default value is 32752.
    • RECFM field: Select one of these record formats:
      • VB: variable blocked (default)
      • VBA: variable blocked with ANSI carriage controls
      • VBM: variable blocked with machine carriage controls

    _______________________________________________________

  2. If the printer is controlled by IP PrintWay™, on the IP PrintWay Options panel, specify:
    • Formatting field: Select None if you do not want IP PrintWay to convert data to ASCII or do any page formatting.

    _______________________________________________________

Tip:
If you need to specify the same fields in more than one printer definition, specify the fields in components. Then, include those components in each printer definition to which the components apply.

Example

This ISPF panel shows how to request no NetSpool formatting and also specify the record size and record format of the output data set.

                             NetSpool Options
 

·
·
·
Formatting . . . . 1 1. None 2. Convert to line 3. Convert to PCL Record size . . 80 RECFM . . . . . 1 1. VB 2. VBA 3. VBM Default owner. . . ________ Embedded attributes prefix . . ___________________________

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014