Starting an external and internal trace of an FSA dynamically
Do these steps to start an external trace or an IP PrintWay™ FSA dynamically. This
example assumes that the FSA name is PRT001 and the FSS name is FSS1.
- If an IP PrintWay FSS
definition exists in the Printer Inventory, select None in
the Trace mode field. This is the default value,
so you do not have to create an FSS definition to select the None value.
_______________________________________________________
- If an IP PrintWay FSA
definition exists for the FSA in the Printer Inventory, select None in the Trace mode field.
This is the default value, so you do not have to create an FSA definition
to specify the none value.
_______________________________________________________
- Start GTF as described in Starting the Generalized Trace Facility (GTF).
_______________________________________________________
- Start FSA PRT001.
_______________________________________________________
- To start tracing FSA PRT001, enter this MODIFY command:
MODIFY FSS1,TRACEON,PRT001,MODE=FULL
Tracing
begins when the FSA is idle or at the next data set boundary.
_______________________________________________________
To stop tracing:
- Enter this MODIFY operator command to stop tracing FSA PRT001:
MODIFY FSS1,TRACEOFF,PRT001
_______________________________________________________
- Stop GTF by entering: P GTF
_______________________________________________________
|