IBM Print Transforms from AFP for Infoprint Server for z/OS
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF


trailer-transform-error-page

IBM Print Transforms from AFP for Infoprint Server for z/OS
G325-2634-02

trailer-transform-error-page

This single-valued attribute indicates whether the transform writes messages for data stream errors and warnings to a trailer page. The trailer page is the last page in the output document. Warnings can indicate degraded output.

Allowed values

You can enter one of these fixed values:

error
The transform writes messages to a trailer page when an error occurs. This option does not apply when fail-on-transform-error=error or fail-on-transform-error=warning because no output document is created when an error occurs.
no
The transform does not write messages to a trailer page.
warning
The transform writes messages to a trailer page when an error or warning occurs. This option does not apply when fail-on-transform-error=warning because no output document is created when an error or warning occurs.
Note:
If the transform fails because of data stream errors or warnings, it does not create an output document. Therefore, to see a trailer page with error and warning messages, specify fail-on-transform-error=no.

Default value

  1. The value selected in the Trailer error page field in the printer definition for the printer.
  2. The value in the AOP_TRAILER_ERROR_PAGE environment variable for the transform.
  3. The warning value.

Go to the previous page Go to the next page