Use the NAS device class when you are using NDMP (Network
Data Management Protocol) operations to back up network-attached storage
(NAS) file servers. The device class is for drives that are supported
by the NAS file server for backups.
Privilege class
To issue this command, you
must have system privilege or unrestricted storage privilege.
Syntax

>>-UPDate DEVclass--device_class_name--------------------------->
>--+--------------------------+--+----------------------+------->
'-LIBRary--=--library_name-' '-MOUNTRetention--=--0-'
>--+-----------------------+--+---------------------------+----->
'-MOUNTWait--=--minutes-' '-MOUNTLimit--=--+-DRIVES-+-'
+-number-+
'-0------'
>--+----------------------+------------------------------------->
'-ESTCAPacity--=--size-'
>--+-------------------------------+---------------------------><
'-PREFIX--=--tape_volume_prefix-'
Parameters
- device_class_name (Required)
- Specifies the name of the device class to be defined. The maximum
length of the device class name is 30 characters.
- LIBRary
- Specifies the name of the defined library object that contains
the SCSI tape drives used by this device class. For information about
defining a library object, see the DEFINE LIBRARY command.
- MOUNTRetention=0
- Specifies the number of minutes that an idle sequential access
volume is retained before it is dismounted. Zero (0) is the only supported
value for device classes with DEVType=NAS.
- MOUNTWait
- Specifies the maximum number of minutes the server waits for an
operator to respond to a request to either mount a volume in a drive
in a manual library or check in a volume to be mounted in an automated
library. This parameter is optional. If the mount request is not satisfied
within the specified amount of time, the mount request is canceled.
You can specify a number 0 - 9999.
- MOUNTLimit
- Specifies the maximum number of sequential access volumes that
can be simultaneously mounted for the device class. This parameter
is optional. You can specify a number 0 - 4096.
If you plan to use the simultaneous-write function, ensure
that sufficient drives are available for the write operation. If the
number of drives needed for a simultaneous-write operation is greater
than the value of the MOUNTLIMIT parameter for
a device class, the transaction fails.
The following are possible
values:
- DRIVES
- Specifies that every time a mount point is allocated, the number
of drives that are defined and online in the library is used to calculate
the true value.
Note: For EXTERNAL library types, do not specify DRIVES for the
MOUNTLIMIT value. Specify the number of drives for the library as
the MOUNTLIMIT value.
- number
- Specifies the maximum number of drives in this device class that
are used concurrently by the server. This value must never exceed
the number of drives that are defined and online in the library that
services this device class.
- 0 (zero)
- Specifies that no new transactions can gain access to the storage
pool. Any current transactions continue and complete, but new transactions
are terminated.
- ESTCAPacity
Specifies the estimated capacity for
the volumes that are assigned to this device class. This parameter
is optional.
You must specify this value as an integer
followed by one of the following unit indicators: K (kilobytes), M (megabytes), G (gigabytes),
or T (terabytes). The smallest value that is
accepted is 1 MB (ESTCAPACITY=1M).
For example, specify that the estimated capacity
is 9 GB with the parameter ESTCAPACITY=9G.
To force the Tivoli® Storage
Manager server to
determine the estimated capacity for the volumes that are assigned
to this device class, specify ESTCAPACITY="".
- PREFIX
- Specifies the high-level qualifier of the data set name that the
server writes into the sequential access media labels. For each sequential
access volume assigned to this device class, the server uses this
prefix to create the data set name. This parameter is optional. The
maximum length of this prefix is 8 characters.
If you have a naming
convention for media labels to support your current management system,
use a volume prefix that conforms to your naming conventions.
Values that are specified for this parameter must meet
the following conditions:
- The value is to be made up of qualifiers, which can be a maximum
of eight characters including periods. For example, the following
value is acceptable:
AB.CD2.E
- The qualifiers must be separated by a single period.
- The first letter of each qualifier must be alphabetic or national
(@,#,$), followed by alphabetic, national, hyphen, or numeric characters.
An
example of a tape volume data set name using the default prefix is
ADSM.BFS.
Example: Update the estimated capacity for a NAS device
class
Update a device class named NASTAPE. Change the estimated
capacity to 200 GB.
update devclass nastape library=naslib estcapacity=200G