DFHOT0103 APPLID A system exception has occurred while processing a GIOP request. The server that was processing the request can be identified by the hostname hostname.

Explanation

A system exception was thrown while a GIOP request was being processed by this server. The hostname identifies the server.

System action

The system exception is returned to the client of the GIOP request.

User response

Investigate the cause of the problem as follows:

  1. Determine if the problem can be explained by any previous messages issued from some other CICS component. Look especially for DFHEJxxx or DFHIIxxx messages.

  2. If a trace is available look for OT, EJ or II exception trace points.

    Also look for II trace points 0132, 0714 and 0201. II 0132 and 0714 trace GIOP requests and replies. If a reply contains a system exception the II 0132 or 0714 is followed by an II 0201 with SYSTEM_EXCEPTION in the trace interpretation.

If you cannot resolve the problem, you need further assistance from IBM. See IBM problem support for guidance on how to proceed.

Module

dfhjjts.jar

XMEOUT parameters/Message inserts

  1. APPLID
  2. hostname

Destination

Console