DFHNC0809 Reload for CF structure strname failed, structure is full.

Explanation

Named counter pool reload processing failed because there are insufficient free entries or elements to store the new data in the structure.

System action

Reload processing is terminated and the server is closed down with message DFHNC0808.

User response

If the structure is currently allocated at less than its maximum size and the coupling facility has enough free space, the size of the structure can be increased dynamically using the MVS SETXCF command with the START,ALTER option, and the reload job can then be run again as soon as the alter request completes, in which case it will skip over duplicate information which has already been successfully reloaded. If the structure is at its maximum size, use the MVS SETXCF FORCE command to delete the structure, then increase the SIZE and INITSIZE parameters in the current CFRM policy and activate the updated policy, and rerun the reload job. The approximate amount of information which could not be reloaded can be estimated by comparing the numbers of blocks read and named counters reloaded, as described by following message DFHNC0803, with the corresponding numbers from message DFHNC0703 in the unload job.

Module

DFHNCRL

Destination

Console and SYSPRINT