DFHNC0481I Waiting for structure strname to become available.
Explanation
The named counter sequence number server was unable to connect to its coupling facility structure because of an environmental error, such as the structure being unavailable, as described in a previous DFHNC0403 message. The server is now waiting for this problem to be fixed, and will retry the connection request when it is notified via the ENF facility that the specific structure may now be available or that some change has occurred in the status of general coupling facility resources.
System action
The server waits to be notified of a relevant event.
User response
No action is required, but the waiting server can optionally be terminated using the MVS CANCEL command if it is no longer required.
Module
DFHNCENDestination
Console and SYSPRINT