DFHNC0408 CF structure strname is not available for exclusive use.

Explanation

The current named counter sequence number unload or reload job requires exclusive use of the pool, but some other job is running which already has shared or exclusive use of the pool. (This serialization uses an MVS ENQ with scope SYSTEMS, major name 'SYSZDFH' and minor name equal to the structure name, 'DFHNCLS_poolname').

System action

The server is terminated.

User response

Check whether a named counter sequence number server or maintenance job is currently running. If it is, wait until it has finished before trying to run the current job again. You can find out what jobs are currently using the pool using this MVS command:


DISPLAY GRS,RES=(SYSZDFH,'DFHNCLS_poolname')

Note that for this command the pool name must be exactly eight characters, padded with trailing spaces if necessary.

Module

DFHNCCF

Destination

Console and SYSPRINT