00E72200

Explanation

Db2 detected an internal inconsistency in sort during parallel query processing. This is a Db2 internal error.

System action

A record is written to SYS1.LOGREC and an SVC dump is requested. The application program abends.

Operator response

Notify the system programmer. Provide a print of the SVC dump to the system programmer.

Problem determination

If you suspect an error in Db2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

The precise problem can be determined only by analyzing the abending module at the point of failure. The register contents at the time of abend are set as follows:
  • R2 points to the SPL.
  • R3 is an unique decimal code that identifies the error location and error type.
Collect the following diagnostic items:
  • Console output from the system on which the job was run, and a listing of the SYSLOG data set for the period of time that spans the failure.
  • Dynamic dump, taken to SYS1.DUMPxx data set, by Db2 (04E and 04F abends).
  • Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.