00E70011

Explanation

During an authorization check for plan or command authorization, an execution unit switch took place to a new execution unit and the new execution unit abended.

System action

The calling execution unit is also abended.

Operator response

Notify the system programmer. Print SYS1.LOGREC. Also print the dump from any previous dump data set if the failing module name is DSNXACKP or the dump title is 'RDS AUTHCHK'.

System programmer response

If you suspect an error in Db2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

See problem determination. If you suspect an error in Db2, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.

Problem determination

The module issuing this abend reason code has invoked the DSNXCHK macro to perform an authorization check for either the application plan or the command authorization. The DSNXCHK macro does a cross-memory execution unit switch to module DSNXACKP. Look for a previous dump in which the failing module name is DSNXACKP, the dump title is RDS AUTHCHK, or the failure is an allocation failure.

Collect the following diagnostic items:
  • Dynamic dump, taken to SYS1.DUMPxx data set, by Db2 (04E and 04F abends).
  • Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.