Integrity checker warning messages
Warning messages do not prevent the integrity checker utility from successfully passing, but you should investigate and correct the causes of warning messages.
WARNING BMXAA0452W
These users should be removed from the security tables because they are not database users:
WARNING BMXAA0454W
The following Security Groups have no Users. This is for your information only, you do not need to take any actions:
WARNING BMXAA0460W
Changes were made to the database that have not been applied. Ensure that the changes are applied in the Database Configuration application.
WARNING BMXAA0461W
The following original indexes are missing. Go to the Database Configuration application and redefine the missing indices.
- Cause
- Indexes that were previously defined are missing.
WARNING BMXAA0463W
The database has a different CLUSTERED property for the following original index definition(s):
WARNING BMXAA0469W
There was no unique index found for the primary key sequence on the table. Determine whether the table requires an index for the primary key column sequence.
WARNING BMXAA0471W
No primary key sequence is defined on the table. Review the table and decide if a primary key sequence is required.
WARNING BMXAA0473W
No unique index was found for the unique column ID on tables.
WARNING BMXAA0475W
The following Maximo database tables should be removed from the database because they do not exist in the schema:
WARNING BMXAA0498W
The following columns are defined to be ''same-as'', but have different must-be settings. Go to the Database Configuration application and fix the mismatch.
- Cause
- There is a mismatch between "must-be" values for columns marked as "same-as"
WARNING BMXAA0507W
This utility cannot repair the column. It is defined the ''Same As'' some other column.
WARNING BMXAA0508W
This utility cannot repair the column because it is defined ''Must Be''.
WARNING BMXAA0509W
This utility cannot repair the column. It is the ''Root'' column for another column.
WARNING BMXAA0510W
This utility cannot repair the column. It cannot decrease the size of a column.
WARNING BMXAA0511W
This utility cannot repair the column. Existing data might violate the definition.
WARNING BMXAA0512W
This utility cannot repair the column because it has a value list associated with it. The value list datatype does not match the root column datatype.
WARNING BMXAA0519W
The following autokeys should be removed from the AUTOKEY system table because they are not referenced by a column.
WARNING BMXAA0520W
More than one application is mapped to same position in a module.
WARNING BMXAA0521W
All applications should be mapped to a table. The following apps are not mapped.
WARNING BMXAA0528W
The following backup tables exist. If the data has been restored and the tables are not required, they should be deleted.
WARNING BMXAA0531W
This column contains values that are not defined in the domain, Column {0} Domain {1}. Update the data to synchronize it with the domain or value list that is defined for the column.
WARNING BMXAA0535W
Domain {0} is defined to be domain type {1}, but has no values in {1} domain.
WARNING BMXAA7114W
The value of the defined scale for this column is invalid. Go to the Database Configuration application and correct the mismatched values.
WARNING BMXAA7113W
The value defined for the length of this column is invalid. Go to the Database Configuration application and correct the discrepancy.
WARNING BMXAA7115W
The following persistent Maximo columns are owned by non-persistent Maximo tables:
WARNING BMXAA7110W
The primary key sequence on the table is not sequential. Review the primary key sequence and ensure that it follows a sequential order and does not contain any gaps.
WARNING BMXAA7726W
Unique column ID does not have the BIGINT maxtype on the following tables:
WARNING BMXAA7109W
Column {0} is mapped to domain {2}, but is not defined the same., {0} is {1}. {2} is {3}. Correct the data and try again.
WARNING BMXAA7112W
{0} definition differs from {1} for {2}.,{0}.{3}={4}{1}.{3}={5}. Use the Database Configuration application to correct the configuration metadata.
WARNING BMXAA7253W
Non-standard domain type found, data not validated against this domain. Domain ID = {0}, Domain Type = {1}.
WARNING BMXAA6259W
Process {0} contains Subprocess {1} which has a process that creates a loop.