FSPSP46

Some corrupt areas of flash or RAM have been detected on the service processor.

  1. Use the following table to determine the action to perform.
    System Action
    8203-E4A, 9407-M15, 9408-M25, 8204-E8A, and 9409-M50 Replace the system backplane (Un-P1). See System FRU locations for information on system FRU location.
    8234-EMA, 9117-MMA, and 9406-MMA Replace the Service Processor.
    1. If the last byte in word 3 of the SRC is a 10, replace the primary unit, service processor (Un-P1-C11).
    2. If the last byte in word 3 of the SRC is a 20, replace the secondary unit 1, service processor (Un-P1-C11).
    9125-F2A Replace the I/O backplane (Un-P1).
    9119-FHA

    Replace the failing CEC service processor card.

    See System FRU locations for information on system FRU location.

    Using the management console, look at the platform ID in the IQYYLOG error log entry to determine the failing system controller.

    • For Platform ID 0x50xxxxxx, replace system controller A at location Un-P1-C2.
    • For Platform ID 0x51xxxxxx, replace system controller B at location Un-P1-C5.
    • For platform ID 0x86xxxxxx, replace bulk power controller A at location Un-P1-C1.
    • For platform ID 0x88xxxxxx, replace bulk power controller B at location Un-P2-C1.
    Example:
    
        |------------------------------------------|
        | Platform Event Log - 0x51EC6DB6          |
        |------------------------------------------|
        |     Private Header                       |
        |------------------------------------------|
        | Section Version   : 1                    |
        | Sub-section type  : 0                    |
        | Created by        : hlth                 |
        | Created at        : 04/21/2010 05:05:17  |
        | Committed at      : 04/21/2010 05:05:17  |
        | Creator Subsystem : FipS Error Logger    |
        | CSSVER            :                      |
        | Platform Log Id   : 0x51EC6DB6           |
        | Entry Id          : 0x51EC6DB6           |
        | Total Log Size    : 496                  |
        |------------------------------------------|
    

    In this example, the platform ID is 0x51, which indicates system controller B should be replaced.

  2. Perform a slow boot. See Performing a slow boot .

This ends the procedure.