End of call procedure for servers with Service Focal Point
For future reference, record the SRC or symptom and
the location code of the FRU you replaced.
On the HMC, open Service Focal Point and examine the
service action event log for any open service action events.
Are there any service action events that are open?
No
If the system attention LED is still on, turn off the LED as described
in Activating
and deactivating LEDs. This completes the repair; return the system
to the customer.
Begin a new list of "Axx" partitions by copying
the list of partitions obtained in step 11. Go to step 16.
Add the partition list obtained in step 11 to
the existing list of "Axx" partitions obtained from processing previous
service action events in this MAP.
Remove all entries in the list of all partitions you
recorded in step 11. If you are referred to the list of partitions obtained in step 11 in future steps, the list is empty.
Go to step 17.
Select and highlight the service action event from
the Error Associated With This Serviceable Event window.
Click Close Event.
Add comments for the serviceable event. Include any
unique additional information. Click OK.
The following steps will add or update FRU information.
Did you replace, add, or modify a FRU of the open
service action event?
Perform the following steps for each entry in the
list of all partitions you recorded in step 11,
except the partition you were using to debug the original problem.
From the HMC virtual terminal window of a partition
in the list of all partitions, type diag at the AIX command prompt.
When the diagnostic operating instructions are displayed,
do the following:
Press Enter.
Select the Task Selection option.
Note: If the terminal type is not defined, you are prompted to define
it before you can proceed.
Select the Log Repair option.
Select the resource associated with the repair action. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action. If the resource associated with your repair
action is not displayed on the Resource List, select sysplanar0.
Click Commit after you have made your
selection.
Exit from diagnostics in this partition and return
to the AIX prompt.
Have all the partitions in the list of all partitions
you recorded in step 11 been
processed?
No
Go to step 27 to process
the next partition in the list you recorded in step 11.
While processing all service action events, were you
directed to step 14?
No
If the system attention LED is still on, turn off the LED as described
in Activating
and deactivating LEDs. This completes the repair. Return the system
to the customer.
Note: If during the processing of the list of open service
action events, some service action events remained open, further service actions
may be required to complete the repair.
Perform the following steps for each entry in the
list of "Axx" partitions you began recording in step 14,
except the partition you were using to debug the original problem.
From the HMC virtual terminal window of a partition
in the list of "Axx" partitions, type diag at the AIX command
prompt.
When the diagnostic operating instructions are displayed,
do the following:
Press Enter.
Select the Task Selection option.
Note: If the terminal type is not defined, you are prompted to define
it before you can proceed.
Select the Log Repair option.
Select the resource associated with the repair action. If the repair action was reseating a cable or adapter, select the resource
associated with that repair action. If the resource associated with your repair
action is not displayed on the Resource List, select sysplanar0.
Click Commit after you have made your
selection.
Exit from diagnostics in this partition and return
to the AIX prompt.
Have all the partitions in the list of "Axx" partitionss
you began recording in step 14 been
processed?
No
Go to step 34 to process
the next partition in the list you recorded in step 14.
Yes
If the system attention LED is still on, turn off the LED as described
in Activating
and deactivating LEDs. This completes the repair. Return the system
to the customer.
Note: If during the processing of the list of open service
action events, some service action events remained open, further service actions
may be required to complete the repair.