POWER7 information

Failing function code C11

The 2.4 GB SCSI disk drive assembly might be failing.

Use the following table to determine the part number for the field replaceable unit (FRU).

CCIN or FFC Type and model Part number Description Location code
C11 Any 36G4280 2.4 GB SCSI disk drive field repair assembly
Note: The field repair assembly includes one disk drive, the electronics backplane, and the 5-1/4 inch form-factor cage. The remaining good drive is removed from the failed disk drive assembly and installed in the field repair assembly to create a complete dual-disk drive assembly. If saving data is critical, try installing the faulty drive in place of one of the two good drives in the now-complete field repair assembly. If the faulty drive operates satisfactorily, the problem was probably in the electronics backplane.
 

If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.