POWER7 information
Failing function code C11
The 2.4 GB SCSI disk drive assembly might be failing.
Use the following table to determine the part number for the field replaceable unit (FRU).
CCIN or FFC | Type and model | Part number | Description | Location code |
C11 | Any | 36G4280 | 2.4 GB SCSI disk drive field repair assembly Note: The field
repair assembly includes one disk drive, the electronics backplane,
and the 5-1/4 inch form-factor cage. The remaining good drive is removed
from the failed disk drive assembly and installed in the field repair
assembly to create a complete dual-disk drive assembly. If saving
data is critical, try installing the faulty drive in place of one
of the two good drives in the now-complete field repair assembly.
If the faulty drive operates satisfactorily, the problem was probably
in the electronics backplane.
|
If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.