Disk events

The following table lists the events that are created for the Disk component.

Table 1. Events for the Disk component
Event Event Type Severity Message Description Cause User Action
disk_down STATE_CHANGE WARNING Disk {0} is reported as not up. A disk is reported as down. This can indicate a hardware issue. If the down state is unexpected, then refer to the Disk issues section in the IBM Spectrum Scale Troubleshooting Guide.
disk_up STATE_CHANGE INFO Disk {0} is up. Disk is up. A disk was detected in up state. N/A
disk_found INFO INFO The disk {0} was found. A disk was detected. A disk was detected. N/A
disk_vanished INFO INFO The disk {0} has vanished. A declared disk was not detected. A disk is not in use for an IBM Spectrum Scale™ filesystem. This could be a valid situation. N/A
disc_recovering STATE_CHANGE WARNING Disk {0} is reported as recovering A disk is in recovering state A disk is in recovering state If the recovering state is unexpected, then refer to the section Disk issues in the Troubleshooting guide
disc_unrecovered STATE_CHANGE WARNING Disk {0} is reported as unrecovered A disk is in unrecovered state A disk is in unrecovered state. The metadata scan might have failed. If the unrecovered state is unexpected, then refer to the section Disk issues in the Troubleshooting guide