If the MR10k MegaRAID card has been replaced and the firmware
is not at the current level, you must update the firmware to current
supported field levels.
Before you begin
The mrdump script is provided to gather the MegaRAID
logs needed by IBM® System x® support to help diagnose problems
with the MR10k card and battery. Enter the following commands on the
command line:
cd /opt/MegaRAID/MegaCli
./mrdump.sh
The script creates two log files (mrlog.log and MegaSAS.log)
in the same directory for support.
The ProtecTIER® software
V2.4.0 or later installs the MegaCli during the autorun command.
- Check whether the /opt/MegaRAID/MegaCli/mrdump.sh command
is present. If it is not, you must install the MegaCli commands for ProtecTIER software
V2.3 and below.
- Display the current firmware versions.
Make a note of the displayed levels and compare them to the levels
listed in this document.
- Update the MR10K firmware.
The update takes several minutes to complete. All components
are updated to supported levels
About this task
The MR10k MegaRAID card provides battery backup of the hard
disk drive (HDD) cache data. This card also provides the mirroring
of the two HDDs used for the operating system (OS). See the
IBM System Storage Problem
Determination and Service Guide for the TS7650 ProtecTIER Deduplication Appliance and
TS7650G ProtecTIER Deduplication
Gateway, GA32-0923, included
on the
IBM System Storage TS7650 with ProtecTIER Publications CD,
for more information. This procedure is used to update the firmware
on the MR10k after a hardware replacement of the adapter.
Attention: Do NOT power off
the system during this operation, doing so might corrupt your system
or risk data integrity.
Procedure
- Connect a universal serial bus (USB) keyboard and monitor
to the server.
- Insert the appropriate software
DVD.
ProtecTIER software
version |
DVD |
2.3 |
IBM System Storage RAS/BIOS
and Firmware Update DVD (if not already inserted) |
2.4 |
ProtecTIER 2.4 DVD
(if not already inserted) |
2.5 or later |
No DVD needed |
- Log with the ID ptadmin and password ptadmin.
- From the command line, enter the following commands to
start the firmware load process:
mkdir /mnt/cdrom
Note: If
the
/mnt/cdrom directory already exists, the following
message is displayed:
mkdir: cannot create directory '/mnt/cdrom': File exists
Ignore
the message and proceed to the next command.
mount /dev/hda /mnt/cdrom
cd /mnt/cdrom
- Enter the following command to update the MR10k MegaRAID
card.
./installMRFW
The updated firmware level is as follows (ServerRAID MR10k):ibm_fw_sraidmr_10k-11.0.1-0022_linux_32-64.bin
Note: The
version listed is subject to change. Download the latest version as
necessary.
- Enter the following command to update the MegaRAID command
line utilities:
./installMRCli
- After a successful update of the MRCli, eject the IBM System Storage RAS/BIOS and Firmware
Update DVD by entering
the following commands:
cd /
eject /dev/hda
Results
The process of replacing the MR10k MegaRAID card and updating
the firmware is complete.
What to do next
If you are performing any other field replaceable unit (FRU)
or firmware updates, proceed to the appropriate section.
Otherwise,
go to End-of-call procedure for the TS7650 Appliance or TS7650G (Gateway), ProtecTIER V3.3.6.