Enclosure events
The following table lists the events that are created for the Enclosure component.
Event | Event Type | Severity | Message | Description | Cause | User Action |
---|---|---|---|---|---|---|
adapter_bios_notavail | STATE_CHANGE | WARNING | The bios level of adapter {0} is not available. | The bios level of the adapter is not available. | N/A | Check the installed BIOS level using the mmlsfirmware command. |
adapter_bios_ok | STATE_CHANGE | INFO | The BIOS level of adapter {0} is correct. | The BIOS level of the adapter is correct. | N/A | N/A |
adapter_bios_wrong | STATE_CHANGE | WARNING | The bios level of adapter {0} is wrong. | The bios level of the adapter is wrong. | N/A | Check the installed BIOS level using the mmlsfirmware command. |
adapter_firmware_notavail | STATE_CHANGE | WARNING | The firmware level of adapter {0} is not available. | The firmware level of the adapter is not available. | N/A | Check the installed BIOS level using the mmlsfirmware command. |
adapter_firmware_ok | STATE_CHANGE | INFO | The firmware level of adapter {0} is correct. | The firmware level of the adapter is correct. | N/A | N/A |
adapter_firmware_wrong | STATE_CHANGE | WARNING | The firmware level of adapter {0} is wrong. | The firmware level of the adapter is wrong. | N/A | Check the installed BIOS level using the mmlsfirmware command. |
current_failed | STATE_CHANGE | ERROR | currentSensor {0} failed. | The currentSensor state is failed. | N/A | N/A |
current_ok | STATE_CHANGE | INFO | currentSensor {0} is ok. | The currentSensor state is ok. | N/A | N/A |
current_warn | STATE_CHANGE | WARNING | currentSensor {0} is degraded. | The currentSensor state is degraded. | N/A | N/A |
dcm_drawer_open | STATE_CHANGE | WARNING | DCM {0} drawer is open. | The DCM drawer is open. | N/A | N/A |
dcm_failed | STATE_CHANGE | WARNING | DCM {0} is failed. | The DCM state is failed. | N/A | N/A |
dcm_not_available | STATE_CHANGE | WARNING | DCM {0} is not available. | The DCM is not installed or not responding. | N/A | N/A |
dcm_ok | STATE_CHANGE | INFO | DCM {id[1]} is ok. | The DCM state is ok. | N/A | N/A |
drawer_failed | STATE_CHANGE | ERROR | drawer {0} is failed. | The drawer state is failed. | N/A | N/A |
drawer_ok | STATE_CHANGE | INFO | drawer {0} is ok. | The drawer state is ok. | N/A | N/A |
drive_firmware_notavail | STATE_CHANGE | WARNING | The firmware level of drive {0} is not available. | The firmware level of the drive is not available. | N/A | Check the installed firmware level using the mmlsfirmware command. |
drive_firmware_ok | STATE_CHANGE | INFO | The firmware level of drive {0} is correct. | The firmware level of the drive is correct. | N/A | N/A |
drive_firmware_wrong | STATE_CHANGE | WARNING | The firmware level of drive {0} is wrong. | The firmware level of the drive is wrong. | N/A | Check the installed firmware level using the mmlsfirmware command. |
enclosure_data | STATE_CHANGE | INFO | Enclosure data found. | Successfully queried the enclosure details. | The mmlsenclosure all -L -Y command reports enclosure data. | N/A |
enclosure_firmware_notavail | STATE_CHANGE | WARNING | The firmware level of enclosure {0} is not available. | The firmware level of the enclosure is not available. | N/A | Check the installed firmware level using the mmlsfirmware command. |
enclosure_firmware_ok | STATE_CHANGE | INFO | The firmware level of enclosure {0} is correct. | The firmware level of the enclosure is correct. | N/A | N/A |
enclosure_firmware_unknown | STATE_CHANGE | WARNING | The firmware level of enclosure {0} is unknown. | The SAS card is unable to read enclosure firmware. | The SAS card does not report the enclosure firmware. | Check the SAS connectivity from node to enclosure. Use the mmlsrecoverygroup rg_name -L --pdisk command to verify if all the paths to pdisk are available. Check the SAS connectivity using a combination of the mmgetpdisktopology and the topsummary command. If there is an issue with the SAS HBA or SAS Cable, reboot the node to see if this resolves the issue. If not contact your IBM representative. |
enclosure_firmware_wrong | STATE_CHANGE | WARNING | The firmware level of enclosure {0} is wrong. | The firmware level of the enclosure is wrong. | N/A | Check the installed firmware level using mmlsfirmware command. |
enclosure_found | INFO_ADD_ENTITY | INFO | Enclosure {0} was found. | A GNR enclosure listed in the IBM Spectrum Scale configuration was detected. | N/A | N/A |
enclosure_needsservice | STATE_CHANGE | WARNING | Enclosure {0} needs service. | The enclosure needs service. | N/A | N/A |
enclosure_ok | STATE_CHANGE | INFO | Enclosure {0} is ok. | The enclosure state is ok. | N/A | N/A |
enclosure_unknown | STATE_CHANGE | WARNING | Enclosure state {0} is unknown. | The enclosure state is unknown. | N/A | N/A |
enclosure_vanished | INFO_DELETE_ENTITY | INFO | Enclosure {0} has vanished. | A GNR enclosure listed in the IBM Spectrum Scale configuration was not detected. | A GNR enclosure, listed in the IBM Spectrum Scale configuration as mounted before, is not found. This could be a valid situation. | Run the mmlsenclosure command to verify that all expected enclosures exist. |
esm_absent | STATE_CHANGE | WARNING | ESM {0} is absent. | The ESM state is not installed . | N/A | N/A |
esm_failed | STATE_CHANGE | WARNING | ESM {0} is failed. | The ESM state is failed. | N/A | N/A |
esm_ok | STATE_CHANGE | INFO | ESM {0} is ok. | The ESM state is ok. | N/A | N/A |
expander_absent | STATE_CHANGE | WARNING | expander {0} is absent. | The expander is absent. | N/A | N/A |
expander_failed | STATE_CHANGE | ERROR | expander {0} is failed. | The expander state is failed. | N/A | N/A |
expander_ok | STATE_CHANGE | INFO | expander {0} is ok. | The expander state is ok. | N/A | N/A |
fan_failed | STATE_CHANGE | WARNING | Fan {0} is failed. | The fan state is failed. | N/A | N/A |
fan_ok | STATE_CHANGE | INFO | Fan {0} is ok. | The fan state is ok. | N/A | N/A |
fan_speed_high | STATE_CHANGE | WARNING | Fan {0} speed is too high | The fan speed is out of the tolerance range | N/A | Check the enclosure cooling module LEDs for fan faults. |
fan_speed_low | STATE_CHANGE | WARNING | Fan {0} speed is too low | The fan speed is out of the tolerance range | N/A | Check the enclosure cooling module LEDs for fan faults. |
no_enclosure_data | STATE_CHANGE | WARNING | Enclosure data and state information cannot be queried. | Cannot query the enclosure details. State reporting for all enclosures and canisters will be incorrect. | The mmlsenclosure all -L -Y command fails to report any enclosure data. | Run the mmlsenclosure command to check for errors. Use the
lsmod command to verify that the pemsmod is loaded. |
power_high_current | STATE_CHANGE | WARNING | Power supply {0} reports high current. | The DC power supply current is greater than the threshold. | N/A | N/A |
power_high_voltage | STATE_CHANGE | WARNING | Power supply {0} reports high voltage. | The DC power supply voltage is greater than the threshold. | N/A | N/A |
power_no_power | STATE_CHANGE | WARNING | Power supply {0} has no power. | Power supply has no input AC power. The power supply may be turned off or disconnected from the AC supply. | N/A | N/A |
power_supply_absent | STATE_CHANGE | WARNING | Power supply {0} is missing. | The power supply is missing | N/A | N/A |
power_supply_failed | STATE_CHANGE | WARNING | Power supply {0} is failed. | The power supply state is failed. | N/A | N/A |
power_supply_off | STATE_CHANGE | WARNING | Power supply {0} is off. | The power supply is not providing power. | N/A | N/A |
power_supply_ok | STATE_CHANGE | INFO | Power supply {0} is ok. | The power supply state is ok. | N/A | N/A |
power_switched_off | STATE_CHANGE | WARNING | Power supply {0} is switched off. | The requested on bit is off, indicating that the power supply has not been manually turned on or been requested to turn on by setting the requested on bit. | N/A | N/A |
sideplane_failed | STATE_CHANGE | ERROR | sideplane {0} failed. | The sideplane state is failed. | N/A | N/A |
sideplane_ok | STATE_CHANGE | INFO | sideplane {0} is ok. | The sideplane state is ok. | N/A | N/A |
temp_bus_failed | STATE_CHANGE | WARNING | Temperature sensor {0} I2C bus is failed. | The temperature sensor I2C bus has failed. | N/A | N/A |
temp_high_critical | STATE_CHANGE | WARNING | Temperature sensor {0} measured a high temperature value. | The temperature has exceeded the actual high critical threshold value for at least one sensor. | N/A | N/A |
temp_high_warn | STATE_CHANGE | WARNING | Temperature sensor {0} measured a high temperature value. | The temperature has exceeded the actual high warning threshold value for at least one sensor. | N/A | N/A |
temp_low_critical | STATE_CHANGE | WARNING | Temperature sensor {0} measured a low temperature value. | The temperature has fallen below the actual low critical threshold value for at least one sensor. | N/A | N/A |
temp_low_warn | STATE_CHANGE | WARNING | Temperature sensor {0} measured a low temperature value. | The temperature has fallen below the actual low warning threshold value for at least one sensor. | N/A | N/A |
temp_sensor_failed | STATE_CHANGE | WARNING | Temperature sensor {0} is failed. | The temperature sensor state is failed. | N/A | N/A |
temp_sensor_ok | STATE_CHANGE | INFO | Temperature sensor {0} is ok. | The temperature sensor state is ok. | N/A | N/A |
voltage_bus_failed | STATE_CHANGE | WARNING | Voltage sensor {0} I2C bus is failed. | The voltage sensor I2C bus has failed. | N/A | N/A |
voltage_high_critical | STATE_CHANGE | WARNING | Voltage sensor {0} measured a high voltage value. | The voltage has exceeded the actual high critical threshold value for at least one sensor. | N/A | N/A |
voltage_high_warn | STATE_CHANGE | WARNING | Voltage sensor {0} measured a high voltage value. | The voltage has exceeded the actual high warning threshold value for at least one sensor. | N/A | N/A |
voltage_low_critical | STATE_CHANGE | WARNING | Voltage sensor {0} measured a low voltage value. | The voltage has fallen below the actual low critical threshold value for at least one sensor. | N/A | N/A |
voltage_low_warn | STATE_CHANGE | WARNING | Voltage sensor {0} measured a low voltage value. | The voltage has fallen below the actual low warning threshold value for at least one sensor. | N/A | N/A |
voltage_sensor_failed | STATE_CHANGE | WARNING | Voltage sensor {0} is failed. | The voltage sensor state is failed. | N/A | N/A |
voltage_sensor_ok | STATE_CHANGE | INFO | Voltage sensor {0} is ok. | The voltage sensor state is ok. | N/A | N/A |