server task online
Places the server that is at this junction in an online operational state.
Syntax
server task instance_name-webseald-host_name online [–i server_uuid] junction_point
Description
The server task online command places the server that is at this junction in an online operational state. The server now resumes normal operation. If a server is not specified, all servers that are at this junction are placed in an online operational state.
Options
–iserver_uuid- Specifies the UUID of the server to place in an online operational state. If a server is not specified, all servers that are at this junction are placed in an online operational state. Use the server task show command to determine the ID of a specific server. (Optional)
instance_name-webseald-host_name- Specifies the full server name of the installed WebSEAL server
instance. You must specify this full server name in the exact format
as displayed in the output of the server list command.
The
instance_namespecifies the configured name of the WebSEAL server instance. Thewebsealddesignation indicates that the WebSEAL service performs the command task. Thehost_nameis the name of the physical computer where the WebSEAL server is installed.For example, the configured name of a single WebSEAL server instance is
default. The host computer name where the WebSEAL server is installed isabc.ibm.com. Then, the full WebSEAL server name isdefault-webseald-abc.ibm.com.If an additional WebSEAL server instance is configured and named
web2, the full WebSEAL server name isweb2-webseald-abc.ibm.com. junction_point- Specifies the name of the directory in the WebSEAL protected object space where the document space of the server is mounted.
Authorization
Users and groups that require
access to this command must be given the c (control)
permission in the ACL that governs the /WebSEAL/ object.
For example, the sec_master administrative
user is given this permission by default.host_name-instance_name/junction_point
Return codes
- 0
- The command completed successfully. Note: For WebSEAL server task commands, the return code is
0when the command is sent to the WebSEAL server without errors. However, even after the command was successfully sent, the WebSEAL server might not be able to successfully complete the command. The WebSEAL server returns an error message. - 1
- The command failed. When a command fails, the pdadmin command
provides a description of the error and an error status code in hexadecimal
format (for example,
0x14c012f2).See "Error messages" in the IBM Knowledge Center. This reference provides a list of the Security Access Manager error messages by decimal or hexadecimal codes.
Example
backappl server
at the /pubs junction point in an online operational
state. To determine the UUID of this junctioned server, run the server
task show command: pdadmin> server task default-webseald-cruz show /pubs Output
is like: Junction point: /pubs
...
Server 1:
ID: 6fc3187a-ea1c-11d7-8f4e-09267e38aa77
Server State: running
Operational State: Offline
Hostname: backapp1.diamond.example.com
...
Current requests: 0
...pdadmin> server task default-webseald-cruz online \