Indicates the name of the user assigned as the creator of the object.
Settability of this property is read-only for most users. For users who have been
granted privileged write access (AccessRight.PRIVILEGED_WRITE), this property is
settable only on create. After initial object creation, this property is read-only for all users.
Indicates the date and time the object was created. The Content Engine server stores dates and times using
Coordinated Universal Time (UTC). For more information, see
Timestamps.
Settability of this property is read-only for most users. For users who have been
granted privileged write access (AccessRight.PRIVILEGED_WRITE), this property is
settable only on create. After initial object creation, this property is read-only for all users.
Indicates the date and time the object was last modified. The Content Engine server stores dates and times
using Coordinated Universal Time (UTC). For more information, see
Timestamps.
Settability of this property is read-only for most users. For users who have been granted privileged
write access (AccessRight.PRIVILEGED_WRITE), this property is read/write. (The read/write access for those
users can only change if a change is made to the ACL on the object store that controls who has privileged write access to objects in that
object store).
The user-readable, provider-specific name of an object. This property is usually the designated Name property of the object's class.
For CmAuditProcessingBookmark and AuditDefinition objects, this property is intended to identify client applications
that process the audit log.
For CmAuditProcessingBookmark objects, this property, in support of the audit disposition feature, identifies the client that created the object.
For AuditDefinition objects, this property identifies a set of audit definitions for a given client or client functionality.
For CmAuditProcessingBookmark and AuditDefinition objects, it is recommended that you set this property.
Specify a unique value to distinguish one client application from another.
Note, however, that the server does not prevent identical display names across multiple
CmAuditProcessingBookmark or AuditDefinition objects. Therefore, the client application is responsible for enforcing uniqueness.
The number of seconds an idle connection can remain in the fixed content device
provider pool before being eligible to be closed and removed from the pool. An idle
connection will be closed when the next operation to the same fixed content device
is performed after this idle period.
The maximum number of seconds to wait for a connection once the limit specified
by the FcpPoolMaxInUse property has been reached. If a connection from the fixed
content device provider pool does become available before this wait time expires,
the request is allowed to proceed.
A representation of the Globally Unique Identifier (GUID), a unique 128-bit number, that is assigned to this Content Engine object when the object is created.
When converted to a string, the Id property is typically depicted as 32 hexadecimal characters enclosed by brackets in the following
format: {xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx}. For example, {3F2504E0-4F89-11D3-9A0C-0305E82C3301}.
For User and Group classes, the Id property takes the value of the
Security Identifier (SID) rather than the 128-bit GUID. The string representation of the
SID is in this example format: S-1-5-21-1559522492-2815155736-3711640725-55269.
When Active Directory is used as the directory service for IBM FileNet P8, calls to
User.get_Id() and Group.get_Id() always return the current SID for the
principal, even if this user or group has only historical SIDs populating the Active
Directory server.
For a given property representation, the Id property has the following characteristics:
PropertyDescription.get_Id() is equal to PropertyTemplate.get_Id(), which is equal to PropertyDefinition.get_PrimaryId().
PropertyDefinition.get_Id() is not equal to PropertyDefinition.get_PrimaryId().
PropertyDefinition.get_Id() is not equal to PropertyDescription.get_Id().
For a newly created document object, you can override the Id property of its associated VersionSeries object
before you save or check in the document for the first time.
Indicates the name of the user who last modified this object.
Settability of this property is read-only for most users. For users who have been granted privileged
write access (AccessRight.PRIVILEGED_WRITE), this property is read/write. (The read/write access for those
users could only change if a change is made to the ACL on the object store that controls who has privileged write access to objects in that
object store).
Specifies the SiteSettings objects associated with a fixed content device. Site settings provide
site-specific, configuration value overrides. For each fixed content device type with settings that can be
overridden, a corresponding subclass of SiteSettings is defined with properties that, if populated,
will override the corresponding properties of the same name on the fixed content device object.
For an EMC Centera fixed content device, this property allows the PoolAddress property to be different, depending
on the site in which the Content Engine server is running. If the Content Engine server is running in a site
that does not correspond to one of the SiteSetting objects, then the PoolAddress property on the
CenteraFixedContentDevice object is used as the default.
For a FileNet Image Services fixed content device, this property allows the CSMCache property to be different
depending on the site in which the Content Engine server is running. If the Content Engine server is running
in a site that does not correspond to one of the SiteSetting objects, then the CSMCache property
on the IMFixedContentDevice object is used as the default.
For a NetApp SnapLock fixed content device, there are currently no properties that may be customized for a
site.
Specifies whether data retention protection is enabled on the IBM® Tivoli®
Storage Manager (TSM) server (true) or not (false).
This property corresponds to the ENABLEARCHIVERETENTIONPROTECTION option
in a TSM options file and must match the data retention protection setting on the TSM server.
Specifies whether files will be compressed before they are sent to the IBM® Tivoli®
Storage Manager (TSM) server (true) or not (false). This property
corresponds to the COMPression option in a TSM options file.
The maximum number of concurrent users that are allowed to wait for a tape to be mounted for a given
IBM® Tivoli® Storage Manager (TSM) fixed content device. The default value is 1. It is recommended
that you set the value of this property, at a minimum, to the number of tape drives available in the TSM tape library.
You can increase the value of this property from its minimum recommended value if the tape is
frequently already mounted or can be mounted quickly. You can also try increasing the value of this property
if you receive an unusually high number of retrieval failures when reading from tape. However,
because each waiting user requires a single TSM session, if you set the value of this property too high it can result
in all of the available TSM sessions being consumed because of too many users waiting for tape access.
The value of this property should be less than the value of the MAXSESSIONS option in the TSM options file, which
specifies the maximum number of simultaneous client sessions that can connect to the server.
Otherwise, the number of concurrent users specified by this property will be limited to the maximum number of
client sessions that are allowed by the MAXSESSIONS option.
The full path of the root directory that contains the configuration options files for the IBM® Tivoli®
Storage Manager (TSM) server. This directory must already exist and must be shared
so that the Content Engine system user has read/write access. You should not modify these
configuration options files directly; they are written to by the Content Engine server whenever various
TivoliFixedContentDevice object properties are changed. Because the TSM server cannot run if
these files are missing or damaged, you should back them up frequently.
If this property is set, it indicates that the Content Engine (CE) server is connected to the
IBM® Tivoli® Storage Manager (TSM) server as a non-Windows TSM client and specifies the
full path of the client directory containing the dsmtca and dsm.sys files. Otherwise, if this
property is not set, it indicates that the CE server is connected to the TSM server as a
Microsoft® Windows® TSM client.
The name of the file space used by the client node (Content Engine server)
to connect to an IBM® Tivoli® Storage Manager (TSM) server. A file space
maps a TSM client node to a particular file system on the client machine.
The file space name must begin with a forward slash ("/").
A collection of the CmTivoliManagementClass management classes
associated with a TivoliFixedContentDevice class. Each management
class represents a specific retention setting, which consists of a retention scheme type
and a retention period, that can be applied to an IBM® Tivoli® Storage Manager server.
The name of the client node (Content Engine server) to connect to the IBM® Tivoli®
Storage Manager (TSM) server. All Content Engine objects that are archived
on the TSM server will be accessed using this client node name.
The client node must be configured to have proper read/write access
and must be allowed to make multiple connections to the TSM server.
A string containing configuration options that are passed to the IBM® Tivoli®
Storage Manager (TSM) server by the TSM client (Content Engine server). These configuration options
override the settings specified in the TSM options files. This string is not normally used
and can contain P8-specific data that is not passed to the TSM server.
The owner name for controlling access to the Content Engine objects that
are archived using the IBM® Tivoli® Storage Manager server.
This property is included for legacy reasons and is normally left blank.
The IP address or computer name of the IBM® Tivoli® Storage Manager (TSM) server.
This property corresponds to the TCPSERVERADDRESS option in a TSM options file.