Use the MODIFY command with the option ‘DISPLAY IZU’ to
display the IZUPRMxx parmlib settings from the most recent z/OSMF server initialization. The display
output is displayed in message IZUG013I.
The display output includes:
z/OSMF home page URI.
AUTOSTART group name, if the command is entered for an autostarted z/OSMF server.
One of the following enablement status values for each of the optional z/OSMF services:
STARTED
Service is enabled.
STOPPED
Service is disabled.
UNSPECIFIED
Service name is not specified in a currently active IZUPRMxx parmlib member and is therefore not
enabled.
The display output also includes the server start time and an indication of how long the server
has been running.
The display output does not reflect any configuration changes that you might have
applied to the IZUPRMxx member after server start-up, such as through the SET IZU or SETIZU
command.
Job name of the currently active z/OSMF server started task. By default, the job name is
IZUSVR1, but your installation might use a different job name.
DISPLAY IZU
Displays the settings for the currently active IZUPRMxx parmlib members. This
cumulative set of values is derived from the currently active parmlib members.
The display
output does not reflect any configuration changes that you might have applied to the IZUPRMxx member
after server start-up, such as through the SET IZU or SETIZU command.
If the command is entered incorrectly, an error message from the WebSphere Liberty run time is
displayed to describe the error. The WebSphere Liberty messages are prefixed by CW
and are described online at the following link: WebSphere Liberty message descriptions.
Example 1
Figure 1 shows the display
output for an autostarted z/OSMF server named IZUSVR1.
Example 2
Figure 2 shows the display output for a
stand-alone z/OSMF server named IZUSVR2.