A71

Explanation

During initialization, the reconfiguration component either could not complete initialization or could not establish a recovery environment. The address portion of the program status word (PSW) contains X'x0rrrA71', where rr is the reason code.

The following reason codes explain the failure:
Code
Explanation
030
A reconfiguration module could not determine the cause of error.
032
A reconfiguration module could not establish a recovery environment.
033
A reconfiguration module could not be loaded.
034
A reconfiguration module could not be called.
035
A reconfiguration module could not obtain a message buffer.
036
A reconfiguration module could not obtain a required resource.
099
A reconfiguration module could not initialize the IPLing processor.

System action

The system loads a non-restartable wait state.

Operator response

Notify the system programmer.

System programmer response

Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Reconfiguration