202
Explanation
During system initialization, the system was initializing the address space to be used for console communications. Initialization of the address space failed.
A hexadecimal reason code in field PSAWTCOD in the prefixed save area (PSA) explains the error:
- Code
- Explanation
- 00008001
- Console communication could not establish a recovery environment.
- 00008002
- An error occurred when the system tried to load a module.
- 00008003
- An error occurred during POST macro processing.
- 00008004
- An error occurred during POST macro processing.
- 00008005
- An error occurred when the system updated the command address space table (CAST).
- 00008007
- An error occurred when the system tried to post IEEVIPL.
- 00008008
- An error occurred when the system tried to attach IEAVM613.
- 00008009
- An error occurred when the system tried to attach IEAVM605.
- 0000800C
- An error occurred when the system tried to attach CNZM1TIM.
- 0000Fccc
- An abend occurred. The completion code is ccc.
System action
The system enters restartable wait state X'202'. The system may issue message IEA367A.
Operator response
Do the following:
- Find the reason code by using the hardware Alter/Display facility to display the contents of location X'40C'. Report the reason code to the systems programmer.
- Perform the restart operation to restart the system.
System programmer response
Do the following:
- Look at the explanation of message IEA367A, if issued.
- Continue diagnosis according to the reason code:
- For reason code X'0000F'ccc, see the description of the abend code.
- For reason code X'00008'xxx, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Source
Console services