03B

Explanation

A module required for continued system operation cannot be found in the system link pack area (LPA).

System action

The system may issue message IEA363I to indicate which module could not be found. The system enters a non-restartable wait state.

Operator response

Report this wait state code to the system programmer and save the console listing.

System programmer response

Examine the console listing and look for message IEA363I to determine the name of the missing module. Execute the IEHLIST utility program to obtain a directory listing of the SYS1.LPALIB data set. Examine this list to determine which required system modules are missing. The missing modules should then be copied into SYS1.LPALIB from the starter system libraries or from a similar back-up source. Ask the operator to reIPL the system and add the missing module to the LPA either by requesting an LPA cold start or by using the MLPA or FIX options.

If the problem recurs and the program is correct, search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the contents of the wait PSW available.

Source

Contents supervision (CSV)