JOB=jobname hh:mm:ss yy.ddd DUMP BY IGG0CLA9 - VSAM CATALOG MANAGEMENT
- Component
- VSAM - Catalog Management (5665-28418)
- Issuing module
- IGG0CLA9 - ESTAE
- Explanation
- An abend occurred during catalog management processing. The ESTAE routine IGG0CLA9 requests an SVC dump, frees storage resources, and backs-out partially defined catalog entries in the VSAM catalogs. Message IEC338I is also issued if a validity check failed on a user field parameter list (FPL) or a catalog parameter list (CPL).
- Associated problem data
- The SDWA variable recording area (SDWAVRA) includes:
Offset Length Meaning 0(0) 8 Contains the characters IGG0CLA9 8(8) 3 Entry point address of IGG0CLA9 11(B) 8 Name of the last routine called 19(13) 3 Entry point address of the last routine called 22(16) 8 Name of the calling routine 30(1E) 3 Entry point address of the calling routine 33(21) 4 Contains the characters CPL= 37(25) 28 CPL for the user