ABEND IN SMF INTERVAL PROCESSING - ROUTINE IEEMB836 JOBNAME=xxxxxxxx
- Component
- System management facility (SMF) (5752-SC100)
- Issuing module
- IEEMB836 - FRR
- Explanation
- An abend occurred during SMF interval processing. In the dump title, xxxxxxxx indicates the name of the affected job. The areas dumped are: SQA, ALLPSA, NUC, LSQA, RGN, LPA, TRT, SWA, and SUM.
- Associated problem data
- The SDWACSCT field in the SDWA contains the name of the module in control at the time of the error.