IEC161I (return code 047) rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat
Explanation
For general information about message IEC161I, see the explanation for return code 001.
Specific information
for this return code: The ACB (access method control block) specifies
improved control interval processing but the data set attributes are
not consistent with this mode of access. One of the following errors
was detected:
- Physical block size was not equal to control interval size.
- The data set was not an entry-sequenced data set or the data/index component of a key-sequenced data set.
- The data set was an index with IMBED or REPLICATE specified.
System action
OPEN processing ends for the data set. The error flag (ACBERFLG) in the ACB (access method block) for the data set is set to 160 (X'A0').
Programmer response
Correct the indicated error and rerun the job.
Module
IDA0192A, IDA0192B
Routing code
11
Descriptor code