IEC900I INVALID ABEND CODE PASSED TO MODULE mod
Explanation
The module is an OPEN/CLOSE/EOV problem determination
routine. It did not recognize the passed abnormal end code, so it
issued an Fxx abnormal end code where xx is
one of the following:
- 13 for OPEN
- 14 for CLOSE
- 17 for CLOSE TYPE=T
- 37 for EOV.
Register 12 contains the abnormal end code passed to the module.
In the message text:
- mod
- The specified module.
System action
The system ends the task.
System programmer response
If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job.
Source
DFSMSdfp
Module
IFG0190P, IFG0200P, IFG0230P, IFG0550P, IGG0196M
Routing code
11
Descriptor code
6