IEC802I   lna LINE TOTALS TRANS=mmm DC=nnn IR=ooo TO=ppp

Explanation

This message is produced, at the request of the user, to indicate total counts for a line being used in BTAM processing.

In the message text:
lna
Line address, in hexadecimal.
TRANS=mmm
Total number of transmissions, in decimal.
DC=nnn
Total number of data check errors, in decimal.
IR=ooo
Total number of intervention required errors, in decimal.
TO=ppp
Total number of non-text time-out errors, in decimal.

Source

Basic telecommunications access method (BTAM)

Routing code

8

Descriptor code

4