IEC170I dev I/O ERROR WHILE LOADING text
Explanation
Where text is one of the following:
- TRANSLATE TABLE FOR mod
- COPY MODIFICATION mod
- GRAPHIC MODIFICATION mod
- FCB mod
- LIBRARY CHARACTER SET mod
- WCGMS id-id-id-id
- STARTING COPY NUMBER
- COPY AND/OR FORMS OVERLAY COUNT
A SETPRT macro instruction was issued for a 3800 printer, and a permanent I/O error was detected for the specified operation. If one of the first five message texts appears, mod is the name of a module; if WCGMS appears, each id is a two-character hexadecimal identifier for a character set. Message IOS000I, which gives detailed information about the I/O error, precedes this message.
In the
message text:
- dev
- The device number.
System action
SETPRT processing ends and places a return code in register 15.
Operator response
Notify the system programmer.
Programmer response
Respond as indicated for message IOS000I.
Source
DFSMSdfp
Module
IGG08111