IEC708I dev,volser,jjj,sss,ddn {-#} DUP VOLSEQ: nnnn AND: nnnn
Explanation
A duplicate volume serial number, VOLSER, has been detected in the volume list for a tape or DASD multivolume data set. All serial numbers in the volume list should be unique. The message text includes the volume sequence positions in the volume list of the duplicated volume serial number.
In the message text:
- dev
- The device number.
- volser
- The duplicated volume serial number.
- jjj
- The job name.
- sss
- The step name.
- ddn{-#}
- The DD name and concatenation number if applicable.
System action
Processing continues. The system will ignore the duplicated volume in the volume list.
Operator response
None
System programmer response
Probable user error. If the system administrator determines this condition should always be considered an error, the MPF (Message Processing Facility) can be used to detect the message and abend the job before data is overwritten or reread.
User response
None
Programmer response
Probable user error. Check whether duplicating volume serial numbers in the volume list is intentional.
Source
DFSMSdfp
Module
IFG0551H
Routing code
2,11
Descriptor code
4