Major call 2
- Action code=4
Major Call 2 is in effect.
- Informational bit flag 4=0 and informational bit flag 5=0
No application is in effect.
- Informational bit flag 0=0 and informational bit flag 1=1
The requested control statement came from SYSIN.
- The original OPTION control statement,
including all operands and corresponding subparameters
OPTION STOPAFT=30,DYNALLOC=3390
- The length of the original OPTION control
statement, including all operands and corresponding subparameters
The original control statement string is 31 bytes long.
- Informational bit flag 8=1
DFSORT must parse the control statement returned by EFSPGM.
- The altered OPTION control statement,
including all operands and subparameters
OPTION STOPAFT=30,DYNALLOC=3380,EQUALS
- The length of the altered OPTION control
statement, including all operands and subparameters
The altered control statement string is 38 bytes long.
- Message list=0
EFSPGM has no messages for DFSORT to print to the message data set. General register 15 is set to zero.
Table 1 shows the original control statement sent to EFS program EFSPGM and the altered control statement returned by EFS program EFSPGM.
Original and Altered Control StatementsControl statement format
|
---|
Original OPTION control statement sent to EFSPGM OPTION STOPAFT=30,DYNALLOC=3390 Altered OPTION control statement returned by EFSPGM OPTION STOPAFT=30,DYNALLOC=3380,EQUALS Where: STOPAFT=30 is the original operand and value |