ADNR appears to be hung
Verify that ADNR is actually hung by first issuing a MODIFY
procname,DISPLAY,GWM command. If no response is received then attempt
to stop (not cancel) the application. See z/OS MVS System Commands, STOP command subsection for more information
about stopping an address space. If the application does not terminate,
then the application is hung. If the hang occurred while the debug-level
ADNR trace was in effect, then collect the following problem documentation
and call IBM® Service:
- Take an SVC dump of the ADNR address space
- Take an SVC dump of TCP/IP address space
- Take an SVC dump of the OMVS address space including its data spaces
- Capture the MVS™ console messages
- Capture the ADNR log messages written to syslogd
If the ADNR debug-level trace was not in effect at the time, then turn on the debug-level ADNR trace, reproduce the problem, collect the problem documentation, and call IBM Service.