Starting RMF in the sysplex
You have to start the RMF™ control session and the data gatherer sessions separately on each system of the sysplex, if you want sysplex-wide reports. The reporting, however, can be done on one system.
We strongly recommend that you start RMF on all systems in a sysplex with the same options. This is essential
for later sysplex reporting. The easiest way to do this is by using
the ROUTE command, as shown in this example:
RO *ALL,S RMF