For a TSO/E session

You can assign PF keys to arbitrary reports for the duration of a Monitor II display session.

RMF™ assigns the first 12 program function (PF) keys as shown in Figure 1. To override these assignments, enter a pound sign (#) in the input area, followed by a report name, and any report options. Then press the PF key you want to assign to the report. The assignment remains for the duration of the Monitor II display session. RMF displays the default options menu after each # command so that you can confirm your PF key assignments.

Example: To associate PF 10 with the device report for devices with numbers 0150 through 0350 and device 0370 you specify:
#DEV NUMBER(0150:0350,0370)

and press PF 10. To request the report, press PF 10. For the duration of your session, PF 10 is associated with this report.

For a TSO/E session, the attention key (PA1) can be used in the same way as for any TSO/E command, as long as the timed update command is not active.