Refresh a report automatically |
{ (30S)}
SINTV {(value[S])}
|
Specifies number of seconds in each measurement interval. |
Stop the session |
{M}
STOP(value {H})/NOSTOP
|
Desired duration of the Monitor II session, in minutes (M),
or hours (H). |
Set delta mode |
DELTA/NODELTA
|
Specifies whether RMF™ should
report total values or values that reflect changes since the previous
measurement. |
Write SMF records |
RECORD/NORECORD
|
Specifies whether measured data is to be written to SMF records. |
Create a hardcopy report |
REPORT{(REALTIME)}/(NOREPORT)
{(DEFER) }
|
Specifies production of printed interval reports of measured
data. |
Create a hardcopy report |
SYSOUT(class)
|
SYSOUT class to which the formatted printed reports are directed. |
Define session options |
MEMBER (list)
|
Parmlib member, or list of members, containing Monitor II background
session options. |
Display and set options |
{OPTIONS}/{NOOPTIONS}
{OPTN } {NOOPTN }
|
Print an options list at the operator console at the start
of the session. |