.-DUMPLD--=--NO------.
>>-+--------------------+--------------------------------------><
| .-NO--. |
'-DUMPLD--=--+-----+-'
'-YES-'
statements: |
PCCU |
dependencies: |
see notes |
Indicates
whether an NCP that has abended should be automatically dumped to
the 3720 or 3745 communication controller disk, and then reloaded
from that disk.
- DUMPLD=NO
- Specifies that the NCP that has abended is not automatically dumped
and then reloaded from that disk.
- DUMPLD=YES
- Specifies that the NCP that has abended is automatically dumped
and then reloaded from that disk.
Note: - The value of DUMPLD is used only if you do not specify DUMPLOAD
on the VARY ACT command, and only if a load is actually performed.
- If you code LOADFROM=EXTERNAL and SAVEMOD=NO on the PCCU definition
statement, the initial load will not use the SAVEMOD value.
- If you code LOADFROM=HOST and SAVEMOD=NO on the VARY ACT command,
and code DUMPLD=YES on the PCCU definition statement, the value of
DUMPLD is not used for the initial load.
- If you specify DUMPLD=YES and allow LOADFROM to default to HOST
and SAVEMOD to default to NO, DUMPLD is forced to NO unless you specify
LOADFROM=EXT on the VARY ACT command.