Static dump of remote NCP (via link station) to host: >>-MODIFY-- --procname--,--DUMP--,--ID--=--link_station_name----> .-,--ACTION--=--COMP-. >--,--DUMPDS--=--name--+--------------------+-------------------> .-,--OPTION--=--STATIC-. .-,--RMPO--=--NO------. >--+----------------------+--+---------------------+------------> '-,--RMPO--=--+-NO--+-' '-YES-' .-,--TYPE--=--NCP-. >--+-----------------+-----------------------------------------><
Static dump of NCP to host: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--ACTION--=--COMP-. >--+--------------------+--+--------------------+---------------> '-,--DUMPDS--=--name-' >--+--------------------------------------+---------------------> '-,--DUMPSTA--=--+-------------------+-' '-link_station_name-' .-,--OPTION--=--STATIC-. .-,--RMPO--=--NO------. >--+----------------------+--+---------------------+------------> '-,--RMPO--=--+-NO--+-' '-YES-' .-,--TYPE--=--NCP-. >--+-----------------+-----------------------------------------><
Static dump of NCP to hard disk: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--OPTION--=--STATIC-. >--,--ACTION--=--STORE--+----------------------+---------------><
Dynamic dump of NCP to host: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--ACTION--=--COMP-. >--,--OPTION--=--DYNA--+--------------------+-------------------> .-,--TYPE--=--NCP-. >--+------------------------+--+-----------------+------------->< | (1) | '-,--DUMPDS--=--name-----'
Transfer CSP or MOSS dump from hard disk to host: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--ACTION--=--COMP-. >--,--TYPE--=--+-CSP--+--+--------------------+-----------------> '-MOSS-' >--+------------------------+---------------------------------->< | (1) | '-,--DUMPDS--=--name-----'
Transfer NCP, CSP, or MOSS dump from hard disk to host: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--TYPE--=--NCP------. >--,--ACTION--=--TRANSFER--+----------------------+-------------> '-,--TYPE--=--+-CSP--+-' +-MOSS-+ '-NCP--' >--+------------------------+---------------------------------->< | (1) | '-,--DUMPDS--=--name-----'
Purge dump from hard disk: >>-MODIFY-- --procname--,--DUMP--,--ID--=--ncp_name-------------> .-,--TYPE--=--NCP------. >--,--ACTION--=--PURGE--+----------------------+--------------->< '-,--TYPE--=--+-CSP--+-' +-MOSS-+ '-NCP--'
Operand | Abbreviation |
---|---|
MODIFY | F |
ACTION=TRANSFER | ACTION=TRANS |
DUMPDS | DS |
DUMPSTA | DST |
OPTION=DYNA | OPT=DYNA or DYNA |
OPTION=STATIC | OPT=STATIC |
RMPO=YES | RMPO or RMPO=Y |
RMPO=NO | RMPO=N |
If procname in the START command was startname, startname must be specified for procname.
If TYPE=CSP or TYPE=MOSS, VTAM transfers the CSP or MOSS dump (taken automatically when the CSP or MOSS fails) from the controller's hard disk or diskette to the host. When the transfer is complete, MOSS purges the dump from the controller's hard disk.
If TYPE=NCP, VTAM transfers the dump from the IBM 3720 or the 3745 Communication Controller hard disk to the host. The dump is not purged.
ACTION=TRANSFER and TYPE=NCP are valid only if an NCP dump is on the controller's hard disk from a previous VARY ACT DUMPLOAD=YES command or because DUMPLD=YES is coded on the PCCU definition statement.
If TYPE=CSP or TYPE=MOSS, VTAM purges the CSP or MOSS dump (taken automatically when the CSP or MOSS fails) from the controller's hard disk.
If TYPE=NCP, VTAM purges an NCP dump previously stored on the IBM 3720 or 3745 Communication Controller hard disk. VTAM does not transfer the dump to the host.
ACTION=PURGE and TYPE=NCP are valid only if an NCP dump is on the controller's hard disk from a previous VARY ACT DUMPLOAD=YES command or because DUMPLD=YES is coded on the PCCU definition statement.
If TYPE=CSP or TYPE=MOSS, VTAM transfers the CSP or MOSS dump (taken automatically when the CSP or MOSS fails) from the controller's hard disk to the host.
If TYPE=NCP, VTAM dumps the NCP and stores the results at the host. The type of NCP dump (static or dynamic) to be taken is specified on the OPTION operand.
Only OPTION=STATIC and ID=ncp_name are allowed if ACTION=STORE is specified. No other operands are allowed.
ACTION=STORE requires NCP Version 5 Release 3 or later.
If ID=link_station_name, this operand must be specified.
If ID=ncp_name, the DUMPDS operand (if specified) overrides any file specification in the PCCU definition statement. If this operand is omitted, VTAM uses the file specified in the PCCU definition statement. If the dump file is not specified on either the MODIFY DUMP command or the PCCU definition statement, the command fails.
If the NCP has been acquired before activation, the DUMPDS operand is required for all non-static dump types including CSP, MOSS, and NCP dump transfers and an NCP dynamic dump. VTAM does not allow static dumps of NCPs that have been acquired before activation.
If the DUMPSTA operand is specified, any previous DUMPSTA specifications (from the VARY ACT command or from the NCP definition) are overridden for this one dump operation. If a null value is specified (that is, if DUMPSTA= is specified), VTAM selects an available link station, giving preference to a channel link station over any SDLC link stations.
If the DUMPSTA operand is omitted, the current dump station name from the VARY ACT command or from the NCP definition (in that order) is used. If the current dump station name is null, VTAM selects an available link station as described above.
F NET,DUMP,ID=ncp_name,DYNA
F NET,DUMP,ID=ncp_name,OPTION=DYNA
When TYPE=NCP and OPTION=STATIC, VTAM checks for the availability of the NCP dump data set. If this data set is not available, the command fails and the NCP remains active.
When ACTION=STORE, issue the DISPLAY DISK command to determine that the automatic dump switch in the controller is set on (DUMPLOAD=YES on VARY ACT command or DUMPLD=YES on the PCCU definition) and that the dump slot for this CCU on the controller's hard disk is empty. If either one of these conditions is not met, no dump to disk will take place, and the NCP will be deactivated.
Note that RMPO can be entered instead of RMPO=YES.
The file to contain this dump can be specified by the operator with the DUMPDS operand of the MODIFY DUMP command, or it can be specified by the system programmer on the CDUMPDS operand of the PCCU definition statement. If neither the DUMPDS operand nor the CDUMPDS operand are specified, VTAM uses the dump file specified by the DUMPDS operand of the PCCU definition statement.
If ACTION=PURGE, purges the CSP dump from the hard disk or diskette in the controller.
The file to contain this dump can be specified by the operator with the DUMPDS operand of the MODIFY DUMP command, or it can be specified by the system programmer on the MDUMPDS operand of the PCCU definition statement. If neither the DUMPDS operand nor the MDUMPDS operand are specified, VTAM uses the dump file specified by the DUMPDS operand of the PCCU definition statement.
If ACTION=PURGE, purges the MOSS dump from the hard disk or diskette in the controller.
If ACTION=TRANSFER or PURGE, the OPTION operand does not apply. If ACTION=TRANSFER, the host file to contain the transferred dump can be specified by the operator with the DUMPDS operand of the MODIFY DUMP command, or it can be specified by the system programmer on the DUMPDS operand of the PCCU definition statement.
If TYPE=NCP and ACTION=COMP, the OPTION operand can be used to specify whether this is to be a dynamic or static dump.