IST999E
VTAM MESSAGE LOST — INSUFFICIENT STORAGE

Explanation

VTAM® tried to issue a message, but sufficient storage was not available. Any text issued by VTAM after INSUFFICIENT STORAGE should be ignored.

System action

Processing continues.

Operator response

If the message can be related to a command, and it is necessary that you see the full message, release storage by deactivating unused major nodes or canceling the job, and reenter the command that caused the message.

If the storage problem persists, enter a DISPLAY BFRUSE command. Save the system log and dump for problem determination.

System programmer response

You might have underestimated storage requirements for the common service area (CSA). Increase storage as required. See z/OS Communications Server: SNA Operation for more information on the DISPLAY BFRUSE command. The z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures provides additional information.

Routing code

2

Descriptor code

3