IST896I
AUTOLOGON WILL BE RETRIED WHEN CONTROLLING PLU IS AVAILABLE

Explanation

VTAM® issues this message when an automatic logon (autologon) session initiation fails because the controlling PLU is not available. The initiate request generated by an autologon has requested notification when the specified resource becomes available. When the resource becomes available, notification will occur (see message IST899I), and the autologons will be re-attempted.

System action

The session setup fails.

Operator response

If the problem is with the SSCP-controlling PLU session, start the controlling PLU (SETLOGON START). You may need to work with a network operator in another domain or network when the controlling PLU does not reside in your domain.

System programmer response

None.

Routing code

2

Descriptor code

5