{ACTLU|ACTPU} RSP DATA DISCARDED FOR ID = nodename — INSUFF STORAGE

Explanation

VTAM® did not have sufficient storage to receive the response data included on ACTLU or ACTPU sent by node nodename. The data was discarded.

System action

Node nodename is deactivated.

Operator response

Enter a DISPLAY BFRUSE or DISPLAY STORUSE command to check the availability of storage. Wait and try the activation of nodename again when storage is available.

If the problem persists, save the system log and dump for problem determination.

System programmer response

Verify that the operator entered the buffer pool or CSA start options as specified in the start procedures.

Increase storage as required. For insufficient storage errors, you might want to redefine your buffer pool or CSA limits. If the start option cannot be modified using the MODIFY VTAMOPTS command, you must modify the VTAM start options file (ATCSTRxx) and restart VTAM to use the start option.

Routing code

8

Descriptor code

4