IST561I
STORAGE UNAVAILABLE: bp BUFFER POOL

Explanation

A VTAM® request for storage from the buffer pool bp could not be satisfied because there was not enough available storage in the buffer pool.

bp is the name of the buffer pool. See the z/OS Communications Server: SNA Network Implementation Guide for an explanation and description of buffer pools and for general information on buffer pool specification and allocation.

System action

The action depends on why the requested storage was needed. Other messages might follow identifying the effect this storage condition has on VTAM.

Operator response

Wait a short time and reenter the command. If VTAM continues to issue this message, enter the DISPLAY BFRUSE command. Save the system log and request a dump for problem determination.

System programmer response

Verify that the operator entered the buffer pool or CSA start options as specified in the start procedures.

Increase storage as required. For insufficient storage errors, you might want to redefine your buffer pool or CSA start options. If the start option cannot be modified using the MODIFY VTAMOPTS command, you must modify the VTAM start options file (ATCSTRxx) and restart VTAM to use the start option.

Routing code

2

Descriptor code

5