IST2400I
NO ADAPTER DIAGNOSTICS PRODUCED FOR resource: reason

Explanation

VTAM® issues this message when a CSDUMP was taken but diagnostics for the associated IBM® 10GbE RoCE Express® interface could not be taken.

In the message text:
resource
The value specified as the RNICTRLE trigger for CSDUMP processing.
reason
The reason the diagnostics could not be taken and can be one of the following:
TRLE NOT FOUND
resource does not exist.
TRLE NOT AN RNIC
resource exists and was found, but the TRLE does not represent a 10GbE RoCE Express interface. Diagnostics can be produced only when at least one TCP/IP stack has an active connection to the 10GbE RoCE Express interface.
TRLE NOT ACTIVE
resource represents a 10GbE RoCE Express TRLE, but the TRLE is not in a state where diagnostics can be produced.
UNSUPPORTED ENVIRONMENT
The message specified as a trigger for a CSDUMP and a 10GbE RoCE Express diagnostic dump is issued in an execution environment which prevents VTAM from generating the 10GbE RoCE Express diagnostic dump.

System action

Processing continues.

Operator response

Depending on the value of reason, take the following action:

System programmer response

Depending on the value of reason, take the following action:

TRLE NOT FOUND and TRLE NOT AN RNIC
  1. Determine the correct TRLE name to use for the 10GbE RoCE Express interface.
  2. Instruct the operator to correct the RNICTRLE trigger value by using the MODIFY CSDUMP command.

UNSUPPORTED ENVIRONMENT


Diagnostics for the 10GbE RoCE Express interface cannot be produced if the message that triggers a CSDUMP and a 10GbE RoCE Express diagnostic dump is issued in certain environments.
  • If an alternate message can be used as the trigger, instruct the operator to issue a MODIFY CSDUMP,MESSAGE=alternate_message, RNICTRLE=resource command to change the message trigger.
  • If only this message can be used as the trigger, instruct the operator to issue a MODIFY CSDUMP,RNICTRLE=resource command to take an immediate 10GbE RoCE Express diagnostic dump, or create automation to take the immediate dump, when the message is seen.

User response

None.

Problem determination

Not applicable.

Source

z/OS® Communications Server SNA

Module

Use the modifiable VTAM start option MSGMOD=YES (f procname,vtamopts,msgmod=yes or f procname,msgmod=yes) to display the issuing module when a message is issued. See z/OS Communications Server: SNA Operation and z/OS Communications Server: SNA Resource Definition Reference for more information about start options.

Routing code

2

Descriptor code

5

Automation

This message is not a candidate for automation.

Example

IST2400I NO ADAPTER DIAGNOSTICS PRODUCED FOR IUT1001D: TRLE NOT FOUND