IST2342I
EE HEALTH VERIFICATION NOT SUPPORTED BY puname

Explanation

During the activation of the EE connection, VTAM® sent Logical Data Link Control (LDLC) probes to the remote partner to determine if all five ports are accessible. VTAM did not receive a response to any of the LDLC probe requests. VTAM continued with the activation of the EE connection between this node and the remote partner. Because VTAM received no replies to its LDLC probe requests, VTAM determined that the remote partner does not support EE health verification.

In the message text:
puname
The name of the switched physical unit.

System action

VTAM continues with the activation of the EE connection.

Operator response

Contact the system programmer.

System programmer response

If EE health verification is required for this PU, contact the remote PU owner about upgrading the PU to support EE health verification probes.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server SNA: SNA

Module

You can display the module that issues a SNA message in the message by setting the MSGMOD start option to YES. See Adding the originating module to the message text for more information about the MSGMOD start option.

Routing code

2

Descriptor code

5

Automation

None

Example

IST2342I EE HEALTH VERIFICATION NOT SUPPORTED BY SWIP1A1