IST1806I
NO DIAL-IN LINE FOUND FOR HPR/IP SWITCHED CONNECTION

Explanation

This message is issued when there are no HPR/IP (Enterprise Extender) lines available to accept a dial in predefined Enterprise Extender (EE) network connection. The lines are defined in the HPR/IP (Enterprise Extender) XCA major node.

System action

Processing continues and the EE connection was not established. The other side of the EE connection (where the dial out was initiated) will eventually discover the connection was not established, and an INOP will be generated (due to a timeout while waiting for a response to EE connection initiation).

Operator response

Save the system log and contact the system programmer for problem determination.

System programmer response

Add lines to one of the GROUPs used to define HPR/IP (Enterprise Extender) predefined connections in the XCA major node. See the z/OS Communications Server: SNA Resource Definition Reference for information about defining EE connections and see the z/OS Communications Server: SNA Network Implementation Guide for general information about Enterprise Extender.

Routing code

2

Descriptor code

5